| SMALL
ROTARY UPS |
|
Series MC (25kVA to 300kVA)
The Series MC is designed to provide the same uncompromising
reliability that our large rotary UPS, but in a package
suitable for a plant or computer room floor. It includes
all of the best features of a rotary power system and
is the ultimate in clean power protection. The Series
MC provides 25kVA to 300kVA of clean conditioned, uninterruptible
power for critical loads such as data centers, emergency
facilities and industrial processes.
- 100% on-lint operation
- Digital metering and controls
- 100% load isolation
- Automatic system bypass
- PLC control and internal fault monitors
- Input voltage tolerance of +10%, -20% without use
of battery
- Electrically operated input and output circuit breakers
- Input frequency tolerance from 45 Hz to 66 Hz (without
battery)
- Battery systems from 5 minutes to 4 hours
- Series EMP Flywheel ready
View
PDF | Download
PDF
|
| LARGE
ROTARY UPS |
|
|
Series XC (250kVA to 2000kVA)
The Series XC motor-generator set absorbs load harmonics
and produces a pure sine-wave output, ideal for any
critical load. By operating the rectifier/charger and
inverter in series as the primary power path, the Series
XC Hybrid™ UPS continuously tests its most critical
components under actual operating conditions. There
is no delay, no transients, no question when the utility
source fails; transfer to battery and to alternate AC
source is seamless. The reliability of those components
to perform in a power outage is constantly being verified.
By providing a physical air gap between the load and
the utility source, the motor-generator set protects
the critical load from high power transients, including
lightning.
- Intelligent Programmable Logic Control (PLC)
- M-G status--Bearings/Windings
- Synchronous Motor
- Synchronous Generator
- Fully automated mode selection--Full UPS, Rotating
Filter Power Conditioner, System bypass
- Synchronized mode initiated without load disruption
- Four line digital alphanumeric display or touch
screen interface
- Silver-plated copper bus
- M-G output filter more reliable than LC filter
- Inherent by the M-G, protection against lightning
& eliminates EM
- Low maintenance, long life design
- No air conditioning required
- Audible fault alarm and lights
- System breakers electrically operated
- Superior motor starting capability
- Input THD filter meets IEEE 519
- Overload protection
- Two Stage Input current limit and battery current
limit for maintenance-free battery
- Direct battery-inverter connection for seamless
transition to battery power
- Clear faults in the load without bypass
View
PDF | Download
PDF
|
NO
BREAK UPS |
|
Series NB (30kVA to 2500KVA)
The Series NB combines proven power protection systems
in one complete package. Standard systems are available
from 30 to 2500 kVA, with voltages from 208 to 600 volts
50/60 Hz. Custom systems to 13,800 volts at 10,000 kW
are available. The heart of the Series NB is the ride-thru
motor-generator with enough rotational energy to protect
the load while the Diesel comes on-line. The motor-generator,
utilizing state-of-the-art controls with "brute
force" mechanical energy storage will take raw
electrical power from the local utility company and
conditions it to computer grade electrical power. Should
normal power fail, the Series NB will start-the back
up engine generator and seamlessly provide continuous
electrical power to the critical load.
- 100% electrical isolation from all utility to load
- 24 x 7 power conditioning
- Back-up generator ready
- “Batteryless” UPS
- Touch screen interface
- Tight voltage regulation, no load to full load during
transition
- Motor starting capability
- Adjustable Ride-through times without starting diesel
& elminates “nusance starts”
- Engine generator operation to 8 hours or more (with
diesel options)
- 20 years plus service life
- Single point contact for all service and maintenance
- Lowest “part count” in the industry
View
PDF | Download
PDF
|
RING
BUS UPS |
|
Ring Bus System
In its search for a fail safe power protection system
that can expand with ever-growing computer loads, the
giant railroad transportation center discovered the
hybrid UPS could be configured in a "Ring Bus"
to meet their special requirements.
The Ring Bus offers several distinct advantages over
traditional paralleling schemes. Primary is the ability
to have an expansion without AC power shutdown to the
critical load during upgrade construction phases. Once
the additional UPS modules and ring tie switchboards
have been added, a four-hour window is needed to check
paralleling capability during Ring Bus operations. No
modification of existing equipment is necessary for
expansion: new UPS modules and ring tie switchboards
are "plugged" into the existing switchboard
by using a bus duct raceway connected to a removable
bus link. A Programmable Logic Controller (PLC) manages
system operations and is configured for infinite expansion
from two to three to four or more UPS modules. Additionally,
the ring bus permits a site with multiple utility sources
to keep the sources independent by its ability to run
modules either in parallel or isolated modes facilitated
by the use of multiple bypasses. This avoids the danger
of any single point causing cascading system failure.
|
| LIGHTING
INVERTER |
|
Series LI
The Series LI emergency lighting inverter system is a
single phase, continuous duty, seamless transfer inverter.
The Series LI is designed to supply reliable, isolated,
clean, regulated emergency power for emergency lighting
and associated controls. An efficient ferroresonant transformer,
microprocessor controlled solid-state PWM inverter and
long lasting battery pack provide immunity to all line
disturbances and power interruptions with no break in
AC output power. Power factor correction and harmonic
attenuation are provided. The synchronous inverter produces
a true uninterrupted output in any mode of operation.
A self-diagnostic monitoring alarm system continuously
advises system status.
PS&C has over 40 years vested in the development
of power conditioning equipment and we always create the
best solution for the task. Our Series LI comes with access
to our “World Class Service Division” which
gives our customers the type of support which is not only
required today, but is mandatory for industry to continue
to move on a daily basis.
- Input AC and DC circuit breakers Included
- Short circuit self-protected
- 90 minutes standard emergency backup
- 24 hour recharge - 15 year warranty, extended life
batteries
- Sine wave output
- Status and alarm port for remote annunciation
View
PDF | Download
PDF
|
| LASER
PROTECTION |
|
Series LCP
The Series LCP module has been developed in order to
protect the communication transmission between buildings
and or stations with not only surge protection, but also
an “on line” UPS module. This “harsh
environment” unit has been designed in support of
the “mission critical” customer for use around
the world. PS&C Series LCP can operate in the most
remote locations where in the input power move around
from the single phase 120V numerous times within an hour.
As an option, the Series LCP takes an input of (220 -
240) voltage at 50 or 60hz power and will deliver clean
isolated 120 volt, single phase, 50hz or 60hz output.
The standard output is achieved via 3 hospital grade duplex
outlets and an isolated ground. The unit further protects
the load by means of an input TVSS for the power and Ethernet/phone.
PS&C also equips the Series LCP with the capability
of “Hot Start” directly from the battery in
order to give the user a few minutes of power when no
source is available.
- All welded construction
- Vibration stabilization under all individual components
- 120 volt transient voltage surge suppression on input
- with visual indication
- Over/under output voltage protection
- Recessed input, output and ground
- Temperature sensor on battery
- Wide input range
- Auto restart
- Air conditioning not required
- Overload protection
- Portable and mounted on casters
View
PDF | Download
PDF
|
|
TRANSIENT VOLTAGE SURGE SUPPRESSOR |
|
PS&C Transient Voltage Surge Suppressor
The Series TVSS has been designed to respond to the many
applications where the cause or threat can be attributed
to a specific source or piece of equipment. When that occurs
and the cause is surge, then a surge suppression device
(TVSS) may be all that you need. It is very cost effective
and can be installed to protect a specific load or one specific
piece of equipment. PS&C offers a UL 1449 Second Edition
listed TVSS product line. The range of this line starts
at the Service Entrance/Main Distribution panel up to 320kA
per phase and goes down to the Secondary Distribution/At
the Load up to 80kA per phase. With MOV-based technology,
these systems provide many options to get maximum value
for you power protection investment. PS&C surge suppression
products can be selected to build a layered protection scheme
for all critical points within the facility.
- UL 1449 Second Edition Listed
- EMI/RFI filtering
- Protection in all modes
- On-line monitoring
- Superior clamping voltages
- Dry contacts for remote monitoring
- Tested to exceed industry standards for longevity
- Thermal cutout for over voltage and high fault current
protection
- Fusing in each suppression mode
- 5-year unlimited replacement warranty
View
PDF | Download
PDF
|
| PS&C
SERIES CONTINUUM |
|
|
PS&C Series Continuum
The Series Continuum Static UPS is an IGBT Rectifier
/ IGBT Inverter and IGBT charger/boost double conversion
on-line, intelligent, universal and heavy duty UPS,
designed for mission critical applications. The continuous
operation technology with 100% rated bypass provides
the highest reliability against input disturbances in
the toughest conditions. All units are microprocessor
controlled and operate with multiple communication protocol.
The Series Continuum UPS systems are easy to install
and service. They can be integrated into any office
or industrial environment.
In addition, the Series Continuum 3-Phase UPS provides
really clean power while reflecting the lowest current
total harmonic distortion back to the input source available
in the industry. Diagnosis and control of both power
and UPS are done easily with the standard 4 inch touch
screen.
-
Maximum uptime and system reliability
On-line, Double Conversion operation 100% Rated
Static bypass switch Low noise
-
Anywhere in the World This UPS is
50/60 Hz standard. One machine, one part number,
one set of spares....its that easy.
-
Quick and easy troubleshooting Real
time status information from the UPS via the network
or telephone line
-
Complete protection, monitoring
and manageability Manageable through Touch Screen,
RS232 software serial port, modem, and network (SNMP)
-
Maximum flexibility at no extra
cost Can be connected anywhere in the network without
the need for additional hardware
-
Approved and certified Complying
to the UL 1778
View
PDF | Download
PDF
|
BACK
|
|